The next step was to boot the VIOS.
下一步是引导VIOS。
DS8300 VIOS pair (source) : hvio1 and hvio2.
DS8300 VIOS对(源):hvio1和hvio2。
NetApp VIOS pair (target) : hvio11 and hvio12.
NetApp VIOS对(目标):hvio11和hvio12。
Source DS8300 VIOS pair names: hvio1 and hvio2.
源ds8300 VIOS对的名称:hvio1和hvio2。
Target NetApp VIOS pair names: hvio11 and hvio12.
目标 NetApp VIOS 对的名称:hvio11 和 hvio12。
To log in, use the VIOS padmin userid and password.
使用 VIOS padmin 用户 ID 和密码登录。
I find the VIOS command line much faster and easier.
我发现VIOS命令行快得多,也更容易。
Run this command on the source VIOS during the migration.
在转移期间,在源vios上运行此命令。
These steps were to check the general health of the VIOS.
这些步骤检查VIOS的健康状态。
Document the current virtual device mappings on each VIOS.
记录每个VIOS上当前的虚拟设备映射。
I noticed that the boot list on each VIOS had changed.
我注意到,每个VIOS上的引导列表改变了。
As a result, vtscsi0 and vtscsi1 is available on VIOS.
因此,可以在VIOS上使用vtscsi0和vtscsi1。
Verify that the same SAN disk can be seen by both VIOS.
确认两个VIOS都可以看到同一个SAN磁盘。
Each POWER6-based system is configured with a VIOS partition.
每个基于POWER6的系统都配置了一个VIOS分区。
Verify the virtual device configuration and status on each VIOS.
检验每个VIOS上的虚拟设备配置和状态。
WWPNs for all FC adapters on all VIOS involved in the migration.
在迁移所涉及的所有 VIOS 上的所有 FC 适配器的 WWPN。
Make sure VIOS has sufficient CPU, memory, and network bandwidth.
保证VIOS具有足够的CPU、内存和网络带宽。
The physical disks must be assigned to both paging VIOS partitions.
这些物理磁盘必须分配给两个分页VIOS分区。
I activated one of the VIOS and waited while it started to boot.
我启动一个VIOS,等待它开始引导。
Paging will normally be provided by the primary paging VIOS partition.
正常情况下,由主分页VIOS分区提供分页功能。
However, none of the VIOS or AIX systems are accessing it at this time.
不过,此时,VIOS或AIX系统均没有访问它。
The supported devices differ between AIX and POWERVM VIOS, as well.
受支持设备在AIX和POWERVM VIOS中有所不同。
Listing 2 shows how to display and switch the active paging VIOS partition.
清单2演示如何显示和切换激活的分页VIOS分区。
Mobility activity is logged on the LPAR and the source and target VIOS.
转移活动被记录在LPAR以及源和目标VIOS上的日志中。
With my pool defined, I observed its Settings from the IVM and the VIOS.
定义了池之后,我在IVM和VIOS上查看它的设置。
The VIOS itself can be installed on either the internal disk or SAN disk.
VIOS 本身可以安装在内部磁盘或 SAN 磁盘上。
RMC connections to the LPAR and the source and target VIOS are established.
在 LPAR 与源和目标 VIOS 之间建立 RMC 连接。
Upon successful verification of the LPAR and VIOS profiles, boot each VIOS.
成功地检验LPAR和VIOS的配置文件之后,引导每个VIOS。
Likewise, the VIOS used to serve DS8300 storage to client LPARs, will also remain.
同样地,用来向客户机LPAR提供DS8300存储的VIOS也将继续存在。
No reconfiguration (apart from the boot list) was required, even for the VIOS.
不需要重新配置(引导列表除外),即使对于VIOS也是如此。